Necessary preliminary work:
Detach right footwell heating duct (1) in direction of arrow from retaining lug (3) and lay to one side slightly.
Installation note: Make sure clip (2) is correctly seated.
Unfasten plug connection (1) and disconnect.
Raise plastic lug (2) slightly and turn fan (4) in direction of arrow.
Remove fan (4) from fan shell (5).
Installation note:
If necessary, raise lug (3) slightly and screw in fan (4) anticlockwise.
Make sure fan (4) is correctly seated in fan shell (5).
Check exact position of lug (2).
BMW X3 Service & Repair Manual > Transmission in general: Checking/topping up oil level in automatic transmission (GA8HP45Z, GA8HP50Z,
GA8HP90Z)
IMPORTANT:
Do not let skin come in contact with transmission oil and do not inhale fuel vapors.
Wear protective gloves.
Ensure adequate ventilation
IMPORTANT:
Use only the approved TRANSMISSION OIL .
To set the correct level, it is mandatory that the service function "T ...