IMPORTANT: After completing work, check transmission oil level and top up if necessary.
Use only the approved TRANSMISSION OIL .
NOTE:
Installation note:
Determine and note down dimension A of output flange (old and new).
Determine and note down dimension B of output flange (old and new).
Determine old dimension C, thickness of shim.
Installation note:
Calculate thickness of new shim:
1. Add old dimension A of output flange (previous) and old dimension C of shim Then subtract old dimension B from old result A+C.
2. Subtract dimension B from dimension A of output flange (new).
3. Then subtract result of step 2 from result of step 1.
BMW X3 Service & Repair Manual > Electronic switching or control units: Replacing suction pressure sensor on pressure pipe (N20, N26)
Necessary preliminary tasks:
Read out the fault memory of the DME control unit.
Switch off ignition.
Unlock connector (1) and remove.
Unfasten screws (2).
Pull suction pressure sensor (3) out of pressure pipe.
Installation note:
Check sealing ring for damage. Replace damaged seali ...