BMW X3 Service & Repair Manual: Removing and installing/replacing actuator drive for fresh/recirculated air flap

BMW X3 Service & Repair Manual / HVAC / Heater with operation / Removing and installing/replacing actuator drive for fresh/recirculated air flap

Necessary preliminary work:

  • Remove RIGHT GLOVE COMPARTMENT WITH HOUSING

Release screws (1).

Detach actuator drive for fresh air/recirculating air flap (2) from heating/air conditioning unit.

Unlock plug connection (3) and disconnect.

HVAC

IMPORTANT: Servomotors must be readdressed in the event of replacement!

Addressing can only be carried out with the BMW diagnosis system.

Service functions:

  • Body
  • Heating and air conditioning function
  • Flap motors
  • Readdress flap motors
    Removing and installing/renewing heating unit
    WARNING: Danger of injury! Refrigerant circuit is under high pressure! Avoid contact with refrigerant and refrigerant fluid. Read and comply with ...

    Removing and installing/replacing footwell temperature sensor
    Necessary preliminary work: Remove SUPPORT FOR DASHBOARD NOTE: For purposes of clarity, the following graphic shows the heater/air conditione ...

    Other materials:

    BMW X3 Owners Manual > Storage compartments: Vehicle features and options
    This chapter describes all standard, country-specific and optional features offered with the series. It also describes features that are not necessarily available in your car, e. g., due to the selected options or country versions. This also applies to safety-related functions and systems. The ...