BMW X3 Service & Repair Manual: Removing and installing/replacing actuator drive for fresh/recirculated air flap

BMW X3 Service & Repair Manual / HVAC / Heater with operation / Removing and installing/replacing actuator drive for fresh/recirculated air flap

Necessary preliminary work:

  • Remove RIGHT GLOVE COMPARTMENT WITH HOUSING

Release screws (1).

Detach actuator drive for fresh air/recirculating air flap (2) from heating/air conditioning unit.

Unlock plug connection (3) and disconnect.

HVAC

IMPORTANT: Servomotors must be readdressed in the event of replacement!

Addressing can only be carried out with the BMW diagnosis system.

Service functions:

  • Body
  • Heating and air conditioning function
  • Flap motors
  • Readdress flap motors
    Removing and installing/renewing heating unit
    WARNING: Danger of injury! Refrigerant circuit is under high pressure! Avoid contact with refrigerant and refrigerant fluid. Read and comply with ...

    Removing and installing/replacing footwell temperature sensor
    Necessary preliminary work: Remove SUPPORT FOR DASHBOARD NOTE: For purposes of clarity, the following graphic shows the heater/air conditione ...

    Other materials:

    BMW X3 Service & Repair Manual > Front trim panel: Replacing front left or right side wall holder
    NOTE: Read contents of BODY, GENERAL. Side wall removed. Transfer the systematic diagram onto the respective holder version. General information: Procedure OBSERVE repair stage 2! Following new body parts are required: (1) Holder, side wall, front (variant 1) (2) Holder, side w ...