Necessary preliminary work:

  • Remove RIGHT GLOVE COMPARTMENT WITH HOUSING

Release screws (1).

Detach actuator drive for fresh air/recirculating air flap (2) from heating/air conditioning unit.

Unlock plug connection (3) and disconnect.

HVAC

IMPORTANT: Servomotors must be readdressed in the event of replacement!

Addressing can only be carried out with the BMW diagnosis system.

Service functions:

  • Body
  • Heating and air conditioning function
  • Flap motors
  • Readdress flap motors
    Removing and installing/renewing heating unit
    WARNING: Danger of injury! Refrigerant circuit is under high pressure! Avoid contact with refrigerant and refrigerant fluid. Read and comply with ...

    Removing and installing/replacing footwell temperature sensor
    Necessary preliminary work: Remove SUPPORT FOR DASHBOARD NOTE: For purposes of clarity, the following graphic shows the heater/air conditione ...

    Other materials:

    BMW X3 Service & Repair Manual > Body repair instructions: Contents of body, general
    Before starting repair work BMW i Checking the body for damage (e.g. following an accident) General notes Quality standard . WORKSHOP EQUIPMENT Safety regulations SAFETY AT WORK Information on VEHICLE PROTECTION INFORMATION ON HAZARDS Material/new part MATERIALS SCIEN ...