BMW X3 Service & Repair Manual: Removing and installing/replacing sensor for automatic recirculated air control (auc)

BMW X3 Service & Repair Manual / HVAC / Heater with operation / Removing and installing/replacing sensor for automatic recirculated air control (auc)

Necessary preliminary work:

  • REMOVING and installing/replacing right microfilter housing cover

Remove filter cover (1) in direction of arrow.

HVAC

Unfasten plug connection (2) and disconnect.

Unlock retaining tab (1) and remove AUC sensor.

HVAC

Installation note: Retaining tab (1) on AUC sensor (2) must not be damaged.

HVAC

    Removing and installing/replacing heater/air conditioner blower
    Necessary preliminary work: Remove TRIM FOR INSTRUMENT PANEL AT BOTTOM RIGHT Detach right footwell heating duct (1) in direction of arrow from ...

    Removing and installing/replacing servodrive for blending flap (left)
    Necessary preliminary work: Remove SUPPORT FOR DASHBOARD Release screws (1). Remove actuator drive (2). Unlock plug connection (3) and di ...

    Other materials:

    BMW X3 Service & Repair Manual > Front axle repair instructions: Safety instructions for handling oil
    WARNING: DANGER OF POISONING if oil is ingested/absorbed through the skin! RISK OF INJURY if oil comes into contact with eyes and skin! Recycling: Observe country-specific waste disposal regulations. Measures if oil is unintentionally released: Personal precautionary measures: Dange ...