BMW X3 Service & Repair Manual: Removing and installing/replacing servodrive for blending flap (left)

BMW X3 Service & Repair Manual / HVAC / Heater with operation / Removing and installing/replacing servodrive for blending flap (left)

Necessary preliminary work:

  • Remove SUPPORT FOR DASHBOARD

Release screws (1).

Remove actuator drive (2).

Unlock plug connection (3) and disconnect.

HVAC

IMPORTANT: Servomotors must be readdressed in the event of replacement! Addressing can only be carried out with the BMW diagnosis system.

Service functions:

  • Body
  • Heating and air conditioning function
  • Flap motors
  • Readdress flap motors
    Removing and installing/replacing sensor for automatic recirculated air control (auc)
    Necessary preliminary work: REMOVING and installing/replacing right microfilter housing cover Remove filter cover (1) in direction of arrow. ...

    Removing and installing/replacing servodrive for blending flap (right)
    Necessary preliminary work: Remove RIGHT GLOVE BOX WITH HOUSING Release screws (1). Detach actuator drive for air mix flap (2). Unlock as ...

    Other materials:

    BMW X3 Service & Repair Manual > Body repair instructions: Blind rivet
    1.0 Recommended tools and equipment Blind riveting tongs Rivet head extension Setting blind rivets: Refer to repair instructions for rivet size. Position bore holes for blind rivets in accordance with specification in repair instructions. If necessary, carry over the positions of ...

    BMW X3 Owners Manual

    BMW X3 Service & Repair Manual

    © 2017-2024 Copyright www.bmwx3tech.com - 0.0089