BMW X3 Service & Repair Manual: Replacing servodrive for blending flap

BMW X3 Service & Repair Manual / HVAC / Heater with operation / Replacing servodrive for blending flap

Necessary preliminary work:

  • Remove SUPPORT FOR DASHBOARD

Release screws (1).

Detach actuator drive for stratification flap (2) from heating/air conditioning unit (4).

Unlock plug connection (3) and disconnect.

HVAC

Servomotors must be readdressed in the event of replacement! Addressing can only be carried out with the BMW diagnosis system.

Service functions:

  • Body
  • Heating and air conditioning function
  • Flap motors
  • Readdress flap motors
    Replacing heat exchanger
    Necessary preliminary work: Remove HEATER IMPORTANT: Before ordering spare parts, determine manufacturer of the installed heater! Inst ...

    Replacing servodrive for footwell flap (automatic a/c)
    Necessary preliminary work: Remove RIGHT GLOVE BOX WITH HOUSING Release screws (1). Detach actuator drive for footwell flap (2). Release ...

    Other materials:

    BMW X3 Owners Manual > Hood: Closing the hood
    Hood open when driving If you see any signs that the hood is not completely closed while driving, pull over immediately and close it securely. Danger of jamming Make sure that the closing path of the hood is clear; otherwise, injuries may result. Let the hood drop from a height of approx. ...

    BMW X3 Owners Manual

    BMW X3 Service & Repair Manual