BMW X3 Service & Repair Manual: Replacing servodrive for blending flap

BMW X3 Service & Repair Manual / HVAC / Heater with operation / Replacing servodrive for blending flap

Necessary preliminary work:

  • Remove SUPPORT FOR DASHBOARD

Release screws (1).

Detach actuator drive for stratification flap (2) from heating/air conditioning unit (4).

Unlock plug connection (3) and disconnect.

HVAC

Servomotors must be readdressed in the event of replacement! Addressing can only be carried out with the BMW diagnosis system.

Service functions:

  • Body
  • Heating and air conditioning function
  • Flap motors
  • Readdress flap motors
    Replacing heat exchanger
    Necessary preliminary work: Remove HEATER IMPORTANT: Before ordering spare parts, determine manufacturer of the installed heater! Inst ...

    Replacing servodrive for footwell flap (automatic a/c)
    Necessary preliminary work: Remove RIGHT GLOVE BOX WITH HOUSING Release screws (1). Detach actuator drive for footwell flap (2). Release ...

    Other materials:

    BMW X3 Service & Repair Manual > Electrical: Switches and relays
    REPLACING POWER DISTRIBUTION MODULE (N20, N52T, N55) Necessary preliminary tasks: Switch off ignition. Disconnect BATTERY NEGATIVE LEAD . Remove left service flap on cowl panel cover. Unlock and pull off all connectors (1) from power distribution module. Remove cover (2). Release n ...