BMW X3 Service & Repair Manual: Replacing desiccant insert for air conditioning system

BMW X3 Service & Repair Manual / HVAC / Condenser and dryer with lines / Replacing desiccant insert for air conditioning system

WARNING: Danger of injury! Refrigerant circuit is under high pressure!

  • Follow safety instructions for handling R 134a refrigerant .
  • Avoid contact with refrigerant and refrigerant fluid.

IMPORTANT: Risk of damage! Restart engine only when A/C system has been correctly filled.

FOLLOW instructions for opening and replacing parts in refrigerant circuit.

If air conditioning system is opened for more than 24 hours: replace desiccant insert for air conditioning system

Follow INSTRUCTIONS ON REPLACING DESICCANT INSERT .

Necessary preliminary tasks:

  • Remove CONDENSER

Undo the plastic screw connection (1).

HVAC

Remove the desiccant insert (1).

Installation note: Replace the sealing ring (3) on the plastic screw connection (2).

HVAC

After installation:

EVACUATE AND FILL A/C SYSTEM

    Removing and installing or replacing capacitor for heating and air conditioning system
    Special tools required: 00 9 030 WARNING: Danger of injury! Refrigerant circuit is under high pressure! Avoid contact with refrigerant and re ...

    Replacing safety pressure switch
    WARNING: Danger of injury! Refrigerant circuit is under high pressure! Follow safety informations for handling R 134a refrigerant . Avoid contact ...

    Other materials:

    BMW X3 Service & Repair Manual > Troubleshooting: Contents of engine electrical system general
    General Information WORKING ON IGNITION SYSTEM REMOVING AND INSTALLING ELECTRONIC CONTROL UNITS WELDING WORK (overload protection of control units) Disconnecting and connecting battery DISCONNECTING AND CONNECTING TEST EQUIPMENT COMPONENT INSPECTION EXTERNAL JUMP-STARTING AID Comp ...

    BMW X3 Owners Manual

    BMW X3 Service & Repair Manual

    © 2017-2023 Copyright www.bmwx3tech.com - 0.0771